Specifications

Voltage supply

Rechargeable battery:

  • PSU413D+ AP : 13,6 Ah, Li-Ion , integrated 2 kV overvoltage protection

Battery:

  • PSU713 BP : 13 Ah

Direct power supply:

  • PSU DC : 2 kV overvoltage protection and reverse voltage protection

 

Additional information is provided in Technical details about the energy supply.

Supply or charging voltage 12...32 VDC (max. 12 W )
Housing

Material:

Weight:

Degree of protection:

 

Dimensions (WHD):

ABS / PC (housing/cover)

920 g (without power supply unit)

IP66 / IP67 / IP68

IP68: 105 days at an immersion depth of 1 m

130 x 240 x 84 mm (without antenna)

Ex certification II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc
Operating temperature -20...+50 °C
Air humidity 15...90 % RH non-condensing
Max. operating altitude ≤ 2000 m
Pollution degree PD2
Storage temperature -20...+50 °C
Display Three-colour LED for signalling the operating state
Operation Solenoid switch to initiate aloha transmission mode
Antenna connector 1)

up to 2 x FME-M

Universal inputs 

2 x analogue or digital

Modes:

  • 0/4...20 mA: Resolution 6,3 µA, max. 23,96 mA, load 96 Ω + 50 Ω + resistance of the zener barrier (see Zener barrier)
  • Digital: max. 5...24 V sensor supply VOUT2), low <0,99 V, high >2,31 V, load 10k086 + 50 Ω + resistance of the zener barrier (see Zener barrier)

 

Additional information is provided in Technical details about the universal inputs.

System time Hardware real-time clock with its own buffer battery (service life >10 years) and automatic time synchronisation with the server

 

Additional information is provided in Technical details about the system time.

Internal sensors

Internal housing temperature

  • Measurement range: -20...+60 °C
  • Resolution: 0,1 °C

Humidity in the housing

  • Measurement range: 0...100 %  RH
  • Resolution: 0,1 %  RH

Outputs

1 x switchable and adjustable sensor supply (5...24 V )

 

Additional information is provided in Technical details regarding the sensor supply VOUT.

Local radio interface 3) Low energy module
USB interface 1 x mini-B USB 2.0 slave for the connection to a PC. The DeviceConfig configuration program must be installed on the PC to enable communication with the myDatalogEASY IoT ATEX .

 

Additional information is provided in Technical details about the USB interface.

Data memory Internal flash memory for up to 61.672 measurment cycles

 

Additional information is provided in Functionality of the internal data memory.

Data type f32 (32Bit floating point)
Data transmission

2G/3G/4G world (myDatalogEASY IoT ATEX 2G/3G/4G World )

  • 2G GPRS 900MHz / 1800MHz
  • 2G GPRS 850MHz / 1900MHz
  • UMTS B1, B2, B5, B8
  • LTE FDD B1, B2, B3, B4, B5, B7, B8, B12, B13, B18, B19, B20, B26, B28
  • LTE TDD B38, B39, B40, B41

2G/M1/NB1 world (myDatalogEASY IoT ATEX 2G/M1/NB1 World )  

  • 2G GPRS 900 MHz / 1800 MHz
  • 2G GPRS 850 MHz / 1900 MHz
  • LTE B1, B2, B3, B4, B5, B8, B12, B13, B20, B25, B26, B28, B66, B85

SIM 4) The following options can be selected using the DeviceConfig configuration program:
  • Integrated SIM chip
  • SIM slot

 

Additional information is provided in Using the external SIM slot

1) The number and assignment of antenna connectors depends on the selected variant of the myDatalogEASY IoT ATEX .

2) If the myDatalogEASY IoT ATEX is operated in areas with a zone 2 explosive atmosphere, it is not permitted to connect external voltages to the universal input.

3) reserved for extenstions

4) In order for the SIM slot to be used, the chargeable feature "Activation code VPN SIM (300539)" must be unlocked or order option "Feature activation VPN SIM (300729)" is required.