Specifications
| Voltage supply | Integrated 14 W PV module and integrated rechargeable buffer battery | ||||||||
| Rechargeable buffer battery | Li-Ion rechargeable battery with a usable capacity of 17 Ah | ||||||||
| Housing |
|
||||||||
| Operating temperature | -30...+58 °C | ||||||||
| Air humidity | 15...90 % RH non-condensing | ||||||||
| Max. operating altitude | ≤ 2000 m | ||||||||
| Contamination level | PD2 | ||||||||
| Storage and transport temperature | -30...+60 °C | ||||||||
| Display |
LED in the terminal compartment to indicate the operating status |
||||||||
| Operation |
|
||||||||
| Antenna connector | Fixed low profile antenna | ||||||||
| Universal inputs |
2 x analogue
Modes:
Additional information is provided in Technical details about the universal inputs. |
||||||||
| System time | Hardware real-time clock with its own buffer battery
(service life >10 years) and automatic time synchronisation with the server
Additional information is provided in Technical details about the system time. |
||||||||
| Internal sensors |
Internal housing temperature
Humidity in the housing
|
||||||||
|
Modbus RTU (Client, formerly master) |
Number of modbus channels that can be processed:
1 x RS485 (2-wire)
Additional information is provided in Technical details about the RS485 interface. |
||||||||
| Outputs | 1 x switchable and adjustable sensor supply (5...24 V )
Additional information is provided in Switchable sensor supply VOUT. |
||||||||
| Local radio interface | Low energy module | ||||||||
| Data memory |
Internal flash memory for up to 13.856 measurement cycles
Additional information is provided in Functionality of the internal data memory. |
||||||||
| Data transmission |
Local radio connection:
2G/M1/NB1 modem
|
||||||||
| SIM | Integrated SIM chip |
1) Depending on ambient and structural conditions