Functionality of the internal data memory
| Structure | Circular buffer |
| Total size | 13.856 measurement cycles |
| Number of sectors | 8 |
| Sector size | 1.732 measurement cycles |
The internal data memory of the Lizzox Pure Flood is designed as a circular buffer with 8 sectors. If the maximum number of data records (13.856 ) is achieved, the sector with the oldest data is deleted fully before new data can be saved in this sector again. This means that the internal data memory at the very least contains the measurement values of the last 12.124 cycles, however at most the measurement values of the last 13.856 cycles.
For this reason, it is recommended to coordinate the transmission cycle and record interval in such a way that a maximum of 12.124 measurement cycles have to be recorded between two transmissions. If it can be expected that individual transmissions fail due to poor network coverage or an alternative record interval is activated via the trigger, this must also be taken into consideration when calculating the measurement cycles that are to be saved.
Additional explanation regarding the functionality of the circular buffer
Data memory after the first measurement cycle:

Data memory after 13.856 measurement cycles:

Data memory after 13.856 +1 measurement cycles: