Output channels

Configuration section to configure the settings for the sensor supply.

Note: The settings for the sensor supply and the warmup time always apply to both measurement channels. An individual configuration for each measurement channel is not possible.

"Output channels" Configuration section

1 freely selectable designation for the output channel "switchable sensor supply (VOUT)"
2 Dropdown liste with sensor/zener barrier combinations for which a suitable configuration has already been preset in the device logic.
off Sensor supply deactivated
User defined The sensor supply and the warmup time can be entered in the corresponding input fields

Important: Observe the important note regarding the determination of VOUT in chapter Technical details regarding the sensor supply VOUT.

"Designation of the sensor/zener barrier combination" For sensor supply and warmup time the preset values of the sensor/zener barrier combination are used.
3 Selection of the sensor supply voltage (5...24 V ) 1)
4 Indicates the amount of time for whicht the sensor supply is switched on prior to a measurement 1)

1) Read only, if a specific sensor/zener barrier combination has been selected in the dropdown list "configuration". In this case, the preset values are displayed in the input fields.