Output channels
Configuration section to configure the settings for the sensor supply.
Note: The settings for the sensor supply and the warmup time always apply to both
measurement channels. An individual configuration for each measurement channel is not
possible.
"Output channels" Configuration section
| 1 | freely selectable designation for the output channel "switchable sensor supply (VOUT)" | |
| 2 | Dropdown liste with sensor/zener barrier combinations for which a suitable configuration has already been preset in the device logic. | |
| off | Sensor supply deactivated | |
| User defined | The sensor supply and the warmup time can be entered
in the corresponding input fields Important: Observe the important note regarding the determination of
VOUT in chapter Technical details regarding the sensor supply VOUT. |
|
| "Designation of the sensor/zener barrier combination" | For sensor supply and warmup time the preset values of the sensor/zener barrier combination are used. | |
| 3 | Selection of the sensor supply voltage (5...24 V ) 1) | |
| 4 | Indicates the amount of time for whicht the sensor supply is switched on prior to a measurement 1) | |
1) Read only, if a specific sensor/zener barrier combination has been selected in the dropdown list "configuration". In this case, the preset values are displayed in the input fields.