Measurement values provided

The following measurement values are provided by the VEL‑R‑5 . The VEL‑R‑5   does not have any user interface nor can it establish a direct connection to the myDatanet server. It therefore depends on the data logger used which of these measurement values are available on the web interface of the myDatanet server.

Surface velocity [m/s]
flow velocity at the water surface based on the phase difference of the reflected signal and taking into account the mounting direction (see Measurement method)
Distance to water surface [mm]
distance to the water surface along the extended sensor axis
Tilt angle [°]
angle of attack of the sensor

0° corresponds to horizontal alignment. Positive values correspond to a counterclockwise tilt, while negative values indicate a clockwise tilt.

Signal-to-noise ratio (SNR) [dB]
The signal-to-noise ratio can be used to determine the quality of the velocity measurement.
Status of the surface velocity [ ]
indicates whether the "surface velocity" measurement is valid

This is a status register with individual flags. Several of these flags can be set simultaneously.

FlagsStatusExplanation
No Bit setOkThe surface velocity colud be determined successfully.
Bit 0 (0x01)SlowzoneThe surface velocity determined is located in the area around the zero point, where the measurement has low reliability (i.e. the slow zone).
Bit 1 (0x02)No peakThe surface velocity could not be determined. The current measurement is entered into the filter for determining the surface velocity with the value "0" unless "Hold" has been activated.
Bit 2 (0x04)HoldThe last known value is held.
Bit 3 (0x08)Hold expiredThe maximum number of times the last known value may be held has been exceeded. The current measurement is entered into the filter for determining the surface velocity with the value "0".
Bit 7 (0x80)ErrorThe measurement could not be carried out due to an internal communication error. The sensor has been reinitialised. The surface velocity is immediately set to 0.
Battery voltage [mV]
current voltage of the battery installed in the VEL‑R‑5
Estimated remaining battery life [h]
remaining time until battery replacement