Connection examples

Important: These connection examples only apply if the sensor is also approved for operation in areas with a zone 0, zone 1 or zone 2 explosive atmosphere and if the ATEX requirements (e.g. distances between the signal lines) are observed and maintained when the sensor is connected.

Connection examples

1 myDatalogEASY IoT ATEX 3 2-wire mA sensor
2 Connection cable 7-pins for sensors 2,8 m (206.602) 4 3-wire mA sensor

Important: This connection example is only permitted if the sensors are "simple electrical equipment" and the ATEX requirements (e.g. distances between the signal lines) are observed and maintained.

Connection examples: Digital modes

1 myDatalogEASY IoT ATEX 3 Isolated relay contact
2 Connection cable 7-pins for sensors 2,8 m (206.602)    

Tip: If a universal input has to be operated in "Meter" channel mode, it must be ensured that the sensor supply VOUT is permanently switched on. However, this greatly increases the energy requirements and thus significantly shortens the operating time of the device.