Measurement instrument

Customer Name of the customer to whom the measurement instrument is assigned
Tags List of the tags that are already assigned to the measurement instrument. This assignment can be cancelled by clicking on the cross next to the title of the tag. The input screen for assigning the tags is opened by clicking on the plus symbol. This enables existing tags to be assigned and new tags to be created.
Serial number Serial number of the instrument
Device class The instrument class of the site and instrument must match for an instrument to be able to be connected to a site. Once the instrument has been created via the server interface, the instrument class can only be changed up until the first connection of the instrument to the server. If an instrument class, that does not match the actual class of the instrument, is selected when the instrument is created it is automatically corrected during the first connection.
Lifecycle state: Phase of the lifecycle the device is currently in

In order to meet the requirements of RED Article 3.3 regarding cybersecurity of radio equipment, the device must at least be in the "provisioned" phase. The device can be moved to this state using the "Provision" button. To ensure compliance, the function of the local interfaces is restricted from this phase onwards. The button is only displayed if the device is in the " " (not set) or "preprovisioned" phase. Devices that were delivered prior to the enforcement of RED Article 3.3 on 1 August 2025 are not automatically transitioned to the "provisioned" phase.

*not supported* Display of life cycle phases is not supported
" " Lifecycle state not set
preprovisioned Device ready for handover to partner (firmware installed)
provisioned Device ready for handover to end customer (firmware and application installed)
claimed Device assigned to a server
fielded Device assigned to a server and linked to a site
decomissioned Device was defective and was decommissioned
Lifecycle flags: Lifecycle flags that are currently set

The lifecycle flags that will be transferred to the device during the next synchronisation are displayed to the left of the arrow symbol. A plus sign in front of the name indicates that the lifecycle flag will be set. A minus sign indicates that it will be deleted. The arrow symbol is only displayed if the state of at least one lifecycle flag is to be changed.

The pencil icon opens the input window for setting or deleting lifecycle flags.

Telephone number Telephone number of the SIM card. The control SMS messages (e.g. wakeup) are sent to this number. Format: +43555837465
Instrument flags Additional information regarding the instrument class (for internal use)
Firmware version Current software version installed on the measurement controller
Last connection In each case, the last time stamp of the affected operation
Last wakeup
Last disconnection
Last transmission error
Last Aloha connection
Wakeup SMS count Number of wakeup SMS sent to this device since the last connection. This counter is reset at/during each successfully established connection.
Device Logic sync Productive If the Device Logic installed on the device and saved on the server do not match, the Device Logic saved on the server is loaded in to the device.
Development (sync) The Device Logic on the device and server are synchronised. The one with the latest time stamp is transferred to the other one.
Development (no sync) The Device Logic on the device and server are not synchronised.
Firmware update Off Firmware update is deactivated.
On As soon as a new version of the selected firmware type is available, this is installed immediately.
Even if tag is missing Firmware is also transferred to the device if the device has not transmitted the current firmware version to the server (NOT RECOMMENDED!).
Allow downgrade Facilitates the installation of an older firmware version than the one on the device (NOT RECOMMENDED!)
Once Performs a single firmware update. If no new firmware is available or the firmware was installed successfully, the firmware update is automatically switched to "OFF".
Ignore The firmware update is deactivated and no information is provided about available firmware updates.
Firmware type Released Only firmware versions that have successfully undergone internal and field testing are installed (this practically eliminates malfunctions).
Release candidate Only firmware versions that have successfully undergone internal testing are installed (malfunctions cannot be excluded).
Beta release Even firmware versions that have not successfully undergone all of the internal tests are installed (malfunctions may occur).
Identification String specifying the hardware platform implemented in the device and the corresponding hardware version (i.e. the rapidM2M module identification).
Prod. rev. Product rev. of the myDataconC3
Article Id Product ID, which consists of the type key specified on the type plate and the product specification stored in the device
Article revision Product revision of the myDataconC3
Article name Product name as specified on the type plate of the device