Record module

The record module records the measurement values. As the record interval and measurement cycle can be selected individually, a record is not saved at the time of every measurement. ADepending on the triggers set by the alarm/trigger module, the record interval is modified, the transmission cycle is changed, the transmission is initiated or a new measurement is triggered, if necessary.

The following tables specify the relevant parameters for the module:

Configuration section Mode Parameter Explanation
Measurement channels ->Trigger
Digital
Cnt.Day
Cnt.Intrvl.
0-20 mA
4-20 mA
0-2 V
0-10 V
RI Execute recording immediately
XM Initiate transmission
ON Activate online mode
RA The alternative record interval should be used.
QX The alternative transmission cycle should be used.
Internal channels -> Trigger --- RI Execute recording immediately
XM Initiate transmission
ON Activate online mode
RA The alternative record interval should be used.
QX The alternative transmission cycle should be used.

Configuration section Parameter Explanation
Basic settings Record interval Time between measurement data recordings
Alternative record interval Time between measurement data recordings, if an alternative record interval should be used because of a trigger being initiated