Record module
The record module records the measurement values. As the record interval and measurement cycle can be selected individually, a record is not saved at the time of every measurement. ADepending on the triggers set by the alarm/trigger module, the record interval is modified, the transmission cycle is changed, the transmission is initiated or a new measurement is triggered, if necessary.
The following tables specify the relevant parameters for the module:
| Configuration section | Mode | Parameter | Explanation |
|---|---|---|---|
| Measurement channels ->Trigger | Digital Cnt.Day Cnt.Intrvl. 0-20 mA 4-20 mA 0-2 V 0-10 V |
RI | Execute recording immediately |
| XM | Initiate transmission | ||
| ON | Activate online mode | ||
| RA | The alternative record interval should be used. | ||
| QX | The alternative transmission cycle should be used. | ||
| Internal channels -> Trigger | --- | RI | Execute recording immediately |
| XM | Initiate transmission | ||
| ON | Activate online mode | ||
| RA | The alternative record interval should be used. | ||
| QX | The alternative transmission cycle should be used. |
| Configuration section | Parameter | Explanation | |
|---|---|---|---|
| Basic settings | Record interval | Time between measurement data recordings | |
| Alternative record interval | Time between measurement data recordings, if an alternative record interval should be used because of a trigger being initiated | ||