Specifications

Voltage supply Battery: Li-SOCl2 cell with 19 Ah
Housing

Material:

PE-HD

Weight:

225 g

Protection class:

IP68 / IP69

IP68: 35 Tage at an immersion depth of 4 m

Dimensions (DL):

57 x 110 mm

Ex certification II 1/2G Ex ia/ib IIB T4...T3 Ga/Gb

 

The seperation surface between the category 1 and category 2 part ist the external thread for process installation (see Overview).

 

Dependence between temperature classes and ambient temperatures:

Temperature classMaximum ambient temperatur
T4-20...+55 °C
T3-20...+70 °C

Operating temperature -10...+70 °C
Extended operating temperature -20...+70 °C

Operation with possible deterioration of connection stability (especially if the capacity of the battery is virtually depleted) outside the normal operating temperature range.

Air humidity 15...90 % RH  non-condensing
Storage and transport temperature -20...+70 °C
Radar sensor

Measurement range:

-5...+5 m/s

Resolution:

0,05 m/s

Min. ripple: 

2 mm

Measurement method:

60 GHz Radar

EIRP:

11 dBm

Angle of aperture:

Blocking distance:

0...30 cm 1)

Mounting angle:

30...60° , recommendation: 45°

max. distance:

20 m 1)

max. installation height:

14 m 2)

min. measurement interval:

10 sec.

Data type

Surface velocity [m/s]:

f32 (32 Bit floating point)

Distance to water surface [mm]: 1)

u16 (16 Bit unsigned)

Angle of inclination [°]:

f32 (32 Bit floating point)

Signal-to-noise ratio (SNR) [dB]:

f32 (32Bit floating point)

   

Battery voltage [mV]:

u16 (16 Bit unsigned)

Estimated remaining runtime [h]:

u32 (32 Bit unsigned)

Surface velocity status []:

u8 (8 Bit unsigned)

Data transmission

Local radio connection:

Range:

up to 20 m

(depending on ambient and structural conditions)

Installation G 1½" thread

1) This is not the vertical distance to the water surface, but the distance to the water surface along the extended sensor axis.

2) Maximum permissible vertical distance to the water surface at an angle of inclination of 45°. For other angles of inclination, the maximum permissible distance is calculated as follows: hmax = 20 m x sin (angle of inclination)