List of determined measurement values
Inputs
For each input of the Jellox Pulse
,the following measurment values are determined.
Which of these measurement values contain valid data depends on the "mode" selected for the
input. If the input is deactivated (mode "off"), all measurement values are set to "NaN". If
the input is operated in "Digital" mode, only the measurement values for "Actuation state"
and "Contact position" contain valid data. The remaining measurement values are set to
"NaN". If, by contrast, the "Counter" mode is selected, only the measurement values "Meter
reading", "Quantity" and "Flow rate" contain valid values. The remaining measurement values
are again set to "NaN".
Actuation state [ ]
Indicates whether the contact is idle state or has been actuated
(0 =^ idle sate, 1 =^ actuated )
Type of contact [ ]
Indicates whether current is flowing through the input
(0 =^ no current flows 1 =^ current flows through the contact)
Counter value ["Meter reading unit"1)]
Meter reading calculated based on the pulses (i.e. sum of pulses × pulse value ×
scaling factor from the "pulse unit" to the "meter reading unit")
Quantity ["Pulse unit"1)]
Quantity per recording (i.e. sum of pulses between two recordings multiplied by he
pulse value)
Flow rate ["Pulse unit"1)/s]
Flow rate per recording (i.e. "Quantity per recording" divided by the time difference
between the recordings)
1) configurable via the input window "Channel settings"
(see Inputs in "Counter" mode)
Remote measurement channels
For each of the sensor modules linked to one of the remote measurement channels of the Jellox Pulse
the following measurment values are determined:
Primary measurement value
E.g. pressure for sensor modules of type "PRE-PT-D30"
Secondary measurement values 1 - 3
E.g. "Temperature of the medium", "max. pressure during a pressure surge" and "min.
pressure during a pressure surge" for sensor modules of type "PRE-PT-D30"
Battery [mV]
Current voltage of the battery installed in the sensor module
Runtime [days]
Remaining time until the next sensor battery replacement
Flags [ ]
E.g. "Status of the system" for sensor modules of type "PRE-PT-D30"
RSSI [dBm]
Radio signal strength between the sensor module and the Jellox Pulse
Internal measurement values
In addition to the measurement values provided by the external sensors, the following
internal measurement values are determined:
RSSI [dBm]
Mobile network signal strength
Battery [V]