App log entries

The app log is opened via the context menu, which is displayed by clicking on the three-dot symbol in the list of sites.

CodeParameterDescription
Shutdown handling
MT.BackupSupplySwitched to buffer batterySupply switched to the internal rechargeable buffer battery.
Supply voltage available againSupply switched back to the supply voltage input (VIN).
Outage timeout expiredTime expired for which a short-term supply voltage failure is ignored.
MT.Shutdown Command to shut down the system issued by the device logic
Software update
MT.ModFwUpdatedIO Controller: <previous version> to <current version>Firmware of the IO controller of the data logger has been updated.
IO Controller: Downgrade suppressed Downgrade to a lower Firmware version has been suppressed for the IO controller of the data logger.
IO Controller: Firmware already up-to-date Firmware of the IO controller of the data logger has not been updated. The latest version is already installed.
IO Controller: Update FAILED Firmware update of the IO controller of the data logger failed.
IO Extension MT-<#>: Updated Firmware of the IO controller of the extension with serial number MT-<#> has been updated.
IO Extension MT-<#>: Downgrade suppressed Downgrade to a lower Firmware version has been suppressed for the IO controller of the extension with serial number MT-<#>.
IO Extension MT-<#>: Firmware already up-to-date Firmware of the IO controller of the extension with serial number MT-<#> has not been updated. The latest version is already installed.
IO Extension MT-<#>: Update FAILED Firmware update of the IO controller of the extension with serial number MT-<#> failed.