| Communication problems (between BLE Radar and
the data logger) |
- Reduce the distance between the BLE Radar and
the data logger, and try to avoid obstacles such as walls and similar.
- The capacity of the battery is virtually depleted.
|
| The measurement values "water level" and "distance" are not plausible |
- The alignment of the BLE Radar is incorrect.
The angle between BLE Radar and the surface to
be measured should be exactly 90° if possible.
- The capacity of the battery is virtually depleted.
- Check whether there are any interfering objects between BLE Radar and the surface to be measured.
- Check whether the flag "Underflow" and or the flag "Level Underflow" are set
for the measurement value "Status of the distance" (see Measurement values provided).
|
| The measurement value "water level" is not plausible |
- Check the values currently saved for "mounting height" and "trimming" on the
BLE Radar .
- The alignment of the BLE Radar is
incorrect. The angle between BLE Radar and
the surface to be measured should be exactly 90° if possible.
- The capacity of the battery is virtually depleted.
- Check whether there are any interfering objects between BLE Radar and the surface to be measured.
- Check whether the flag "Level Underflow" is set for the measurement value
"Status of the distance" (see Measurement values provided).
|