Ex protection
The portable BLE Radar is designed for use in areas with a zone 1 explosive atmosphere.
The following conditions must be observed:
- The device is designed for fixed installation and cannot be used as a portable equipment in potentially explosive atmospheres.
- Equipment must be installed in a place with low risk of mechanical impact and shall be adequately protected from falling objects.
- Non-metallic parts of the equipment enclosure shall be protected from direct sunlight.
- The plastic surface of the housing of the device exceeds the limit specified in the standard, so it must be protected against electrostatic charging. Cleaning should only be done with a damp cloth.
- Do not open the housing in the presence of an explosive atmosphere.
- The built-in battery shall be replaced in a non-hazardous area and only the original battery supplied by the manufacturer may be used for replacement. It is forbidden to recharge the power supply cell in the device.
- Only the manufacturer's original spare parts must be used.
- A mounting distance of min. 50 mm must be maintained on all sides to prevent any impurities.
II 2G Ex ib IIB T4
Gb
Important: The Ex approval is only valid if the corresponding marking is provided on
the type plate of the device .
Important: The certificates of conformity and any relevant test certificates from the
respective authorities must be carefully observed during installation and
commissioning.
| 1 | BLE Radar |