Fixed mounts

For the installation of the BLE Radar , fixed mounts are available for various installation situations (see Assembly sets). The alignment of the BLE Radar with the flume to be measured is carried out for all fixed mounts using the procedure described below.

Aligning the BLE Radar using a laser distance meter

1 Laser meter Bosch GLM50-27CG (301757)
2 Laser meter adapter Bosch PRO GLM 50-xxx (301756, optional accessory)
3 Level sensor holder
  1. First, install the sensor bracket that is suitable for your installation situation. You will find further information in the chapters Wall/ceiling mounting (fixed mount) and Mounting on the ceiling of the sewer.
  2. Activate the laser distance meter and insert it into the optional accessory "Laser meter adapter Bosch PRO GLM 50-xxx " (301756). Then position the laser meter adapter in the holder for the level sensor.

     

    The following laser distance meters are compatible with the adapter:
    • Bosch PRO GLM 50-27 CG
    • Bosch PRO GLM 50-27 C
    • Bosch PRO GLM 50-25 G
    • Bosch PRO GLM 50-23 G
    • Bosch PRO GLM 50-22
    • Bosch PRO GLM 40-31

    Inserting the laser distance meter into the level sensor holder

    1Laser meter Bosch GLM50-27CG (301757)
    2Laser meter adapter Bosch PRO GLM 50-xxx " (301756)
    3Level sensor holder
  3. Loosen all nuts. Move the three adjustment nuts by turning them forwards or backwards to align the sensor mount. Use the laser beam of the laser distance meter to determine the point at which the water level is to be measured. The use of three mounting points allows precise adjustment of the sensor mount in all spatial directions.

    Aligning the sensor mount

    1 Nut for locking in position
    2 Nut for adjusting alignment
    3 Sensor mount (wall/ceiling mounting)
  4. Secure the sensor mount by tightening the three locking nuts again.
  5. Remove the Laser meter adapter Bosch PRO GLM 50-xxx from the level sensor mount. Then insert the BLE Radar into the level sensor mount and secure it using the G 1½" union nut supplied with the BLE Radar .

    Inserting the BLE Radar into the level sensor holder

    1 BLE Radar
    2 G 1½" union nut
    3 Level sensor holder