List of determined measurement values

Remote measurement channels

For each of the sensor modules linked to one of the remote measurement channels of the Jellox Node , the following measurment values are determined:

Primary measurement value
e.g. Level (mounting height and trimming taken into consideration) for sensor modules of type "LVL-R-5"
Secondary measurement value 1 - 3
e.g. "Distance to surface", "Amplitude (energy received for the distance determined)" and "Temperature of the electronics" for sensor modules of type "LVL-R-5"
Battery [mV]
current voltage of the battery installed in the sensor module
Runtime [days]
remaining time until the next sensor battery replacement
Flags [ ]
e.g. "Status of the distance" for sensor modules of type "LVL-R-5"
RSSI [dBm]
Radio signal strength between the sensor module and the Jellox Node

 

Internal measurement values

In addition to the measurement values provided by the external sensors, the following internal measurement values are determined:

SOC [%]
State of Charge of the internal battery of the Jellox Node
Battery [V]
current voltage of the the internal battery of the Jellox Node
Int. temp [°C]
internal device temperature of the Jellox Node
rH [%]
humidity in the housing of the Jellox Node
Note: If the humidity in the housing exceeds 95 %, the Dehumidification (301736) service can be ordered.
GSM [dBm]
Mobile network signal strength
Service [Days]
remaining days until the next replacement of the batteries of the Jellox Node
Load [mAs]
Energy consumption between two recordings