Wall mounting
The following optional accessory sets are required for wall mounting:
- 1 x Wall bracket for Jellox with protection casing (400109)
- 1 x Multi band rod antenna with connection cable 250 mm (400110)
|
Wall mounting step 2 |
| 1 | Mounting bracket (included in the scope of supply of 400109) |
| 2 | Pan head screw with sheet metal screw thread ST6,3x60 Torx 30 (included in the scope of supply of 400109) |
| 3 | Multi band rod antenna with connection cable 250 mm (400110) |
| 4 | Seal for detecting tampering (optional) |
| 5 | Jellox Node |
- Drill the four holes with a diameter of 10 mm and a minimum depth of 60 mm in accordance with the dimensions specified in figure Wall mounting step 1 for the wall plugs (10x50) that are included in the scope of supply of the mounting kit.
- Insert a wall plug (included in the scope of supply) into each of the four drilled holes before you screw the mounting bracket (1) to the wall.
- Connect the Multi band rod antenna
with connection cable 250 mm to
the antenna connector of the Jellox Node .
Tip: Depending on the installation situation, it may be more practical to connect the Multi band rod antenna with connection cable 250 mm after inserting the Jellox Node into the mounting bracket.
Connecting the mobile network antenna
1 Antenna connector 2 Multi band rod antenna with connection cable 250 mm - Insert the Jellox Node into the mounting bracket bottom
first. Tilt the Jellox Node forward (i.e. away from the
wall) to position the top of the Jellox Node underneath the
upper brace of the mounting bracket.
Inserting the Jellox Node
1 Jellox Node 3 Mounting bracket 2 Upper brace of the mounting bracket 4 Connection cable 7-pins for sensors 2,8 m - Press the top of the Jellox Node towards the wall until
the lug of the protective armour is fully engaged in the upper brace of the mounting
bracket.
Locking the Jellox Node in place
1 Lug of the protective armour 2 Upper brace of the mounting bracket - Insert the Multi band rod antenna
with connection cable 250 mm into the designated slot in the upper brace of the mounting bracket.
Inserting antanna step 1
Inserting antenna step 2
1 Multi band rod antenna with connection cable 250 mm 2 Antenna slot - Pass the sealing wire through the opening in the upper brace of the mounting bracket
and through the retaining lug of the protective armour. Form a closed loop and insert both
ends of the sealing wire through the seal. Ensure that the sealing wire is tight but not
under tension. Secure the seal by pressing it together with sealing pliers. If necessary,
document the process in accordance with internal company guidelines.
Caution: Cut the wire ends cleanly to prevent injury.
Installing the security seal
1 Opening for security seal or anti-theft device 3 Lug of the protective armour 2 Security seal