Jellox Pulse with internal antenna

1/4: Check your order

  1. Please check the order against the delivery slip to ensure it is complete.

    The components illustrated below are included in each Jellox Pulse set. However, the sets may also contain other components.

    1 Connection cable 7pin 8 m
    2 Jellox Pulse
    3 MDN Magnet

2/4: Create a site

If you do not have an account yet, you will receive the web address of the server, the access data and any credit balance from your responsible sales partner.
  1. Log in to the server via the web interface.

  2. Click on "Customer". Select an existing customer or create a new one.

    Only if you have an account to manage multiple customers.

    1 Menu item to call up the list of customers 3 List of available customers
    2 Creating a new customer    

  3. Click on "Sites / Applications". Open the wizard for creating a new site by clicking on the plus symbol (2).

    1 Menu item to call up the list of existing sites / applications 2 "Add new site / application" symbol

  4. Follow the wizard instructions through to the "Done" step. 

    The serial number required for the Wizard can be found on the type plate of the device.

  5. Review the details in the summary and create the site by clicking the "Create site" button.

    By clicking "create site", the site that is subject to fees will be created.

    1 This amount is debited from the customer's account for this site immediately upon creation and subsequently on a monthly basis.
    2 Checkbox to accept the general terms and conditions
    3 Link to the general terms and conditions
    4 "Create site" button

  6. Review the created site.

    1 Name of the site. Click on the name to open the specific input screen for configuring the site.
    2 Product name as specified on the type plate of the device
    3 Serial number of the device linked to the site
    4 State of the site

3/4: Activate the inputs

Only active inputs can be configured via the "guided commissioning" process in the next step.
  1. Click on the name of the site to open the specific input screen for configuring the site.

    1Site name

  2. Click on the row of the measurement channel that you want to configure to open the window for the settings.

    1Row representing a measurement channel

  3. Select the mode for the measurement channel.

    Next, click "Apply" to close the input window, and then click "Save" to save your selection.

    1 Available modes for the measurement channel
    Off Measurement channel deactivated
    Digital Digital input (Detecting the switching state of a digital contact)
    Counter Infinite counter (Adding up the pulses of a water meter)
    2 Button to apply the settings
    3 Button to save the settings

4/4: Commission the Jellox Pulse

  1. Connect the meter to the Connection cable 7pin 8 m . The wire pair assigned to a measuring channel is displayed at the beginning of the row representing the measuring channel.

    Protect the connection point between the connection cable and the meter in a suitable manner against the ingress of moisture and dust.

    1Colours of the wire pair that is assigned to the measuring channel

    A detailed explanation on how to connect a meter is provided here

  2. Connect the Connection cable 7pin 8 m to the sensor connector of the Jellox Pulse .

    1Sensor connector (7-pin MIL connector)
    2Connection cable 7pin 8 m

  3. Start the "Guided commissioning" process

    Click the button that displays the current status of the measurement system, and select the "Start commissioning" option from the menu that opens.

    1Current operating mode of the measurement system
    2Entry to start the guided commissioning process
  4. The "Guided commissioning" wizard first prompts you to establish a connection.

    To do so, hold the MDN Magnet on the spot shown in the following illustration until all segments of the circle are green.

    How-To-Video: Triggering a connection

    1 MDN Magnet 2 Jellox Pulse

    A detailed explanation of the display is provided here

  5. Open the relevant wizards to configure the individual components one by one and follow the instructions. At last, open the "wizard to complete the set-up" (5).

    Not every component needs to be configured immediately. You can also configure the Jellox Pulse later via the individual input windows or you can restart the guided commissioning process.

    1 Opens the wizard for the basic configuration of the measurement system
    2 Opens the wizard to configure an input operated in "Digital" mode
    3 Opens the wizard to configure an input operated in "Counter" mode
    4 Opens the wizard to configure a remote sensor module of type PRE-PT-D30
    5 Opens the wizard to complete the commissioning process

 

Congratulations!

You have successfully commissioned your Jellox Pulse !

Tell us about your experience with the commissioning process. Your feedback is important to us.

 

Feedback form